Storage of motor, gear, hydraulic and industrial oils in 1000 l IBC totes with access to every tote straight through the gates. Heating is optional: water-based, boiler in an outdoor cabinet, not a single heating appliance in the storage room.

The quote will open in a print window — choose “Save as PDF” there.
Top view. Totes stand tightly in two rows without an aisle: every front-row place is opened by gates across the full width of the tote: a forklift or crane truck places a front-row tote straight onto its spot, a back-row tote is rolled over the deck with a pallet jack. The layout changes with length and selected options — heating puts radiators on the back wall and a cabinet at the end, dispensing stations add a dispensing niche.
“Heating” option. Oil may not be heated in the warehouse with an electric appliance — neither ordinary nor explosion-proof. We move the heat source outside the storage room: the boiler is in an insulated cabinet outside, and only radiators with heat transfer fluid remain inside.
| Requirement | What the regulation says | How we do it |
|---|---|---|
| PUE, cl. 7.4.25 | The use of electric heating appliances is prohibited in fire hazardous zones of warehouse premises | No electric heaters in the storage room |
| Fire Regulations No. 1479, cl. 293 | Electric heating appliances may not be used in warehouse premises; switching devices are located outside the warehouse | Boiler and panel in an outdoor cabinet, light switch outside by the gates |
| SP 60.13330.2020, table B.1, item B.11 | Electric heating — except for warehouses of categories V1–V4; water heating is permitted | Water heating, heat transfer fluid not above 70 °C |
| SP 60.13330.2020, cl. 6.4.3 | Heating appliances in rooms of categories V1–V4 must have protective screens | Screens of non-combustible perforated sheet 100 mm from the appliance |
| Fire Regulations No. 1479, cl. 298 “d” | Filling and packaging of liquids in the storage room are not permitted | Dispensing through a niche in the outer wall, nozzle outside |
Boiler in an outdoor cabinet, only radiators inside — complies with PUE cl. 7.4.25, Fire Regulations cl. 293 and SP 60 without reservations (“Heating” option)
Gates along the full storage length: every tote is placed through the gates, there is no aisle inside, totes stand tightly
A steel bund over the whole area holds more than one IBC tote, drained through a valve outside
Oil is dispensed outside through a niche in the wall — into vehicles or containers; no filling in the storage room
Four lengths and eight options with prices, a preliminary quote immediately, without a request
One factory-ready block: systems installed and tested, transported by an ordinary truck
Four lengths: 3 m — 4 IBC totes of 1000 l, 6 m — 8, 9 m — 12, 12 m — 18. Totes stand tightly in two rows without an aisle: a front-row tote is placed by forklift through the gates, a back-row tote is rolled over the grating deck with a pallet jack.
Motor, gear, hydraulic and industrial oils and lubricants with a flash point above 61 °C — in 1000 l IBC totes. For flammable liquids there is a separate product — the flammable liquids storage block container.
Heating is optional, +15…+20 °C. There are no electric heaters in the storage room: they are prohibited by PUE cl. 7.4.25 and Fire Regulations cl. 293. The boiler is in an insulated cabinet outside; inside there are only radiators with heat transfer fluid no hotter than 70 °C, covered by screens of non-combustible perforated sheet. Climatic version U1 — from minus 45 to plus 40 °C; for colder regions — UHL1 per questionnaire.
Under the floor there is a steel bund over the whole warehouse area, its capacity exceeds one IBC tote. The bund is drained through a valve outside. The totes stand on a grating deck above the bund.
Yes, the “Dispensing stations” option: pneumatic pumps in the tote necks, hoses on reels, dispensing nozzles with meters brought out into a niche in the outer wall. Oil is dispensed outside into vehicles or containers — there is no filling in the storage room, as required by Fire Regulations cl. 298 “d”. The option includes an 80 l used oil collector.
It is a factory-ready modular oil store — a fuel and lubricants warehouse for oils and lubricants in containers: combustible liquids with a flash point above 61 °C, room category V1, no hazardous zone. Gasoline, solvents and other liquids with a flash point of 61 °C and below are not stored in it — for them there is the flammable liquids storage block container in the explosion-proof version.
Standard configuration price incl. 22 % VAT: 3 m — 1,371,000 ₽, 6 m — 1,996,000 ₽, 9 m — 2,705,000 ₽, 12 m — 3,467,000 ₽. The price with options is calculated in the configurator above, a preliminary quote is available immediately. Lead time — 45 business days from the advance payment, delivery separately. The warehouse arrives as one block 2440 mm wide — transported by an ordinary truck without a special permit.
Yes, URMKS is the manufacturer: the oil warehouse is made factory-ready, 12-month warranty. Offices are in Chelyabinsk and the Moscow Region (Serpukhov). To buy a warehouse, assemble the configuration in the configurator and leave a request — we will send a quote with the price and lead time.
Leave your phone or e-mail — a manager will clarify which oils and what volume you store and how many grades you dispense, select the length and equipment and send a quote with the price and lead time.
| № | Item | Qty | Price, ₽ |
|---|
| Subject of the offer | Manufacture and delivery of a factory-ready unit |
| Lead time | 45 business days from receipt of the advance payment, including 15 for design documentation |
| Offer validity | 30 calendar days from the date of issue |
| Price is stated | incl. 22 % VAT |
| Warranty | 12 months from the date of signing the transfer document. Purchased components and equipment are covered by their manufacturers' warranty according to their technical documentation. Valid subject to compliance with the operating manual; does not cover mechanical damage after acceptance, installation on an unprepared base, self-repair or design changes without the manufacturer's approval |
Storage of motor, gear, hydraulic and industrial oils in 1000 l IBC totes. Gates along the full storage length: front-row totes are placed through the gates by the customer's forklift or crane truck straight onto their spots, back-row totes are rolled over the deck with a pallet jack — no aisle is needed inside. The floor is a steel bund over the whole area under a grating deck. Water heating, the boiler is moved to an outdoor cabinet — not a single heating appliance in the storage room. Option — oil dispensing stations with a dispensing niche in the wall. Supplied as one block, systems installed and tested at the factory.


| Code | Dimensions, mm | 1000 l IBC totes | Storage area | Gates 2100 mm high | Dispensing stations (option, one per grade) |
|---|---|---|---|---|---|
| SM-3.0 | 3 000 × 2 440 × 2 700 | 4 — two rows of 2 | 6.2 m² | 1 × 2 400 | up to 4 |
| SM-6.0 | 6 000 × 2 440 × 2 700 | 8 — two rows of 4 | 12.9 m² | 2 × 2,400, common opening 4,800 without a post | up to 8 |
| SM-9.0 | 9 000 × 2 440 × 2 700 | 12 — two rows of 6 | 19.6 m² | 3 × 2,400, frame posts between the openings | up to 12 |
| SM-12.0 | 12 000 × 2 440 × 2 700 | 18 — two rows of 9 | 26.3 m² | 4 × 2,400 and 1 × 1,200, frame posts between the openings | up to 18 |
With the “Heating” option an insulated utility cabinet is installed at the end: the unit length increases by 0.4 m, with dispensing stations — by 0.55 m. Width 2,440 mm — transported without a special permit. Lifting and transport — only without totes.
Combustible liquids with a flash point above 61 °C — room category V1, no hazardous zone, general industrial IP54 equipment.
Not allowed: gasoline, solvents, acetone and any liquids with a flash point of 61 °C and below — for them there is the flammable liquids warehouse in the explosion-proof version. Filling, draining and packaging are not performed inside the storage room.
Oil may not be heated in the warehouse with an electric appliance — neither ordinary nor explosion-proof. The heat source is moved outside the storage room.
| Requirement | What the regulation says | How we do it |
|---|---|---|
| PUE, cl. 7.4.25 | Electric heating appliances are prohibited in fire hazardous zones of warehouse premises | No electric heaters in the storage room |
| Fire Regulations No. 1479, cl. 293 | Electric heating appliances are prohibited in warehouses; switching devices are located outside the warehouse | Boiler and panel in an outdoor cabinet, light switch outside |
| SP 60.13330.2020, table B.1, item B.11 | Electric heating — except for warehouses of categories V1–V4; water heating is permitted | Water heating, heat transfer fluid not above 70 °C |
| SP 60.13330.2020, cl. 6.4.3 | Heating appliances in V1–V4 rooms must have protective screens | Screens of non-combustible perforated sheet 100 mm from the appliance |
Is heating needed. For storage — no: oil and IBC totes tolerate frost. It is needed for dispensing viscous oils in winter: gear oils 80W-90 and TAp-15V need +20…+25 °C, the others are fine at +15 °C.


U1 per GOST 15150-69 — from minus 45 to plus 40 °C. For regions with a design temperature below minus 45 °C — UHL1 version, scope and price per questionnaire.
Subject — manufacture and delivery of a factory-ready unit. Lead time — 45 business days from the advance payment. Delivery, installation on site, connection and commissioning are not included in the price and are agreed separately.